<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Omvormers on GbbOptimizer — Handleiding</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/</link><description>Recent content in Omvormers on GbbOptimizer — Handleiding</description><generator>Hugo</generator><language>nl</language><atom:link href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/index.xml" rel="self" type="application/rss+xml"/><item><title>Victron</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/victron/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/victron/</guid><description>&lt;h1 id="victron"&gt;Victron&lt;a class="anchor" href="#victron"&gt;#&lt;/a&gt;&lt;/h1&gt;
&lt;span class="badge" style="background-color: #3498db; color: white; padding: 2px 8px; border-radius: 4px; font-size: 0.75em; font-weight: 600; text-transform: uppercase; vertical-align: middle;"&gt;victron-only&lt;/span&gt;

&lt;p&gt;De configuratie van een Victron-omvormer met GbbOptimizer vereist een correcte instelling van het &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/references/glossary/#ess" class="glossary-term" title="Energy Storage System"&gt;ESS&lt;/a&gt;-systeem en het &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/references/glossary/#vrm" class="glossary-term" title="Victron Remote Management-portaal"&gt;VRM&lt;/a&gt;-portaal.&lt;/p&gt;
&lt;h2 id="checklist"&gt;Checklist&lt;a class="anchor" href="#checklist"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;p&gt;Controleer de volgende instellingen voordat je GbbOptimizer start:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;&lt;strong&gt;Installeer geen Beta-versies&lt;/strong&gt; van de firmware&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;DESS moet uitgeschakeld zijn&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Schedules&lt;/strong&gt; — de optie „Self-consumption above limit&amp;quot; moet worden ingesteld op &lt;strong&gt;PV&lt;/strong&gt; (en niet op „PV &amp;amp; Battery&amp;quot;). Zo veroorzaken de schema&amp;rsquo;s &amp;rsquo;s nachts geen ontlading van de batterij&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Battery Life&lt;/strong&gt; in &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/references/glossary/#ess" class="glossary-term" title="Energy Storage System"&gt;ESS&lt;/a&gt; moet &lt;strong&gt;uitgeschakeld&lt;/strong&gt; zijn — kies de modus: &lt;code&gt;Optimized (without BatteryLife)&lt;/code&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Log interval&lt;/strong&gt; (in VRM Online Portal) instellen op &lt;strong&gt;1 min&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;VRM-rechten&lt;/strong&gt; — de gebruiker moet het recht &lt;strong&gt;Full Control&lt;/strong&gt; hebben&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Herstart de Cerbo&lt;/strong&gt; na het doorvoeren van de wijzigingen&lt;/li&gt;
&lt;/ol&gt;
&lt;blockquote class='book-hint warning'&gt;
&lt;p&gt;Onjuiste instellingen van Battery Life of Schedules kunnen onverwachte nachtelijke ontlading van de batterij veroorzaken.&lt;/p&gt;</description></item><item><title>Deye</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/deye/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/deye/</guid><description>&lt;h1 id="deye"&gt;Deye&lt;a class="anchor" href="#deye"&gt;#&lt;/a&gt;&lt;/h1&gt;
&lt;span class="badge" style="background-color: #9b59b6; color: white; padding: 2px 8px; border-radius: 4px; font-size: 0.75em; font-weight: 600; text-transform: uppercase; vertical-align: middle;"&gt;deye-only&lt;/span&gt;

&lt;p&gt;Deye-hybride omvormers kunnen op meerdere manieren met GbbOptimizer worden verbonden. Op deze pagina vind je een checklist met de instellingen van de omvormer en een vergelijking van de verbindingsmethoden.&lt;/p&gt;
&lt;h2 id="checklist"&gt;Checklist&lt;a class="anchor" href="#checklist"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;p&gt;Controleer op de Deye-omvormer voordat je GbbOptimizer start:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;
&lt;p&gt;&lt;strong&gt;Werkingsmodus&lt;/strong&gt; — &lt;code&gt;Zero export to CT&lt;/code&gt; of &lt;code&gt;Zero export to Loads&lt;/code&gt; (niet „Selling First&amp;quot;!)&lt;/p&gt;
&lt;blockquote class='book-hint warning'&gt;
&lt;p&gt;Controleer de werkingsmodus niet tijdens een actieve ontlading — GbbOptimizer wijzigt de modus tijdelijk.&lt;/p&gt;</description></item><item><title>GoodWe</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/goodwe/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/goodwe/</guid><description>&lt;h1 id="goodwe"&gt;GoodWe&lt;a class="anchor" href="#goodwe"&gt;#&lt;/a&gt;&lt;/h1&gt;
&lt;p&gt;Voor de configuratie van een GoodWe-omvormer met GbbOptimizer moet toegang worden verleend via het SEMS-portaal en moeten er instellingen worden gedaan aan de GbbOptimizer-zijde.&lt;/p&gt;
&lt;h2 id="stap-voor-stap-configuratie"&gt;Stap-voor-stap configuratie&lt;a class="anchor" href="#stap-voor-stap-configuratie"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;Log in op het &lt;strong&gt;SEMS&lt;/strong&gt;-portaal (GoodWe)&lt;/li&gt;
&lt;li&gt;Voeg in het menu &lt;strong&gt;Beheer&lt;/strong&gt;, bij de gegevens van je installatie, het e-mailadres &lt;code&gt;gbbsoft@gbbsoft.pl&lt;/code&gt; toe als &lt;strong&gt;Gast&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;Voeg in GbbOptimizer een installatie toe met GoodWe, maar &lt;strong&gt;selecteer geen SerialNo&lt;/strong&gt; — de lijst moet leeg zijn (met uitzondering van de tekst „SerialNo kiezen&amp;quot;)&lt;/li&gt;
&lt;li&gt;Vink onderaan de pagina &lt;strong&gt;De installatie delen met technische ondersteuning&lt;/strong&gt; aan&lt;/li&gt;
&lt;li&gt;Neem contact op met de technische ondersteuning (bijv. via Discord: &lt;code&gt;gbbsoft&lt;/code&gt;) en geef het &lt;strong&gt;SerialNo&lt;/strong&gt; van je omvormer door&lt;/li&gt;
&lt;li&gt;De technische ondersteuning selecteert jouw SerialNo&lt;/li&gt;
&lt;/ol&gt;
&lt;blockquote class='book-hint note'&gt;
&lt;p&gt;De configuratie van GoodWe vereist een eenmalige actie van de technische ondersteuning om het serienummer van de omvormer aan jouw installatie te koppelen.&lt;/p&gt;</description></item><item><title>Afore</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/afore/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/afore/</guid><description>&lt;h1 id="afore"&gt;Afore&lt;a class="anchor" href="#afore"&gt;#&lt;/a&gt;&lt;/h1&gt;
&lt;p&gt;Configuratie van de Afore-omvormer met GbbOptimizer. GbbOptimizer stuurt de Afore-omvormer aan via het &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/references/glossary/#modbus" class="glossary-term" title="Serieel communicatieprotocol voor industriële apparaten"&gt;Modbus&lt;/a&gt;-protocol.&lt;/p&gt;
&lt;h2 id="mapping-van-gbboptimizer-modi-op-afore-instellingen"&gt;Mapping van GbbOptimizer-modi op Afore-instellingen&lt;a class="anchor" href="#mapping-van-gbboptimizer-modi-op-afore-instellingen"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;table&gt;
 &lt;thead&gt;
 &lt;tr&gt;
 &lt;th&gt;Bewerking&lt;/th&gt;
 &lt;th&gt;Register&lt;/th&gt;
 &lt;th&gt;Waarde&lt;/th&gt;
 &lt;th&gt;Na afloop&lt;/th&gt;
 &lt;/tr&gt;
 &lt;/thead&gt;
 &lt;tbody&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;AC charging maximum SOC&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Laden: doel-&lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/references/glossary/#maxsoc" class="glossary-term" title="Maximaal gewenste laadtoestand"&gt;MaxSOC&lt;/a&gt;&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;ACCharging start/end time (1-4)&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Laden: array van de volgende 4 perioden&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Forced charging start/end time (1-4)&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Laden: array van de volgende 4 perioden&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;ACCharging power percentage&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Laden: Input Limit&lt;/td&gt;
 &lt;td&gt;% van MaxBuyPower of MaxBatteryChargeDC&lt;/td&gt;
 &lt;td&gt;Oorspronkelijke waarde herstellen&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Forced charging power percentage&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Laden: Charge Limit&lt;/td&gt;
 &lt;td&gt;% van MaxBatteryChargeDC&lt;/td&gt;
 &lt;td&gt;Oorspronkelijke waarde herstellen&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Minimum SOC for forced discharge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Ontladen: doel-&lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/references/glossary/#minsoc" class="glossary-term" title="Minimale drempel voor de laadtoestand"&gt;MinSOC&lt;/a&gt;&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Forced discharge start time (1-4)&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Ontladen: array van de volgende 4 perioden&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Power grid power limit percentage&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Ontladen: &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/references/glossary/#gridsetpoint" class="glossary-term" title="Gewenste vermogensuitwisseling met het net in watt"&gt;GridSetpoint&lt;/a&gt;&lt;/td&gt;
 &lt;td&gt;% van MaxSellPower of MaxBatteryDischargeDC&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Maximum charging current&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Laadblokkering: ingesteld op &lt;code&gt;0&lt;/code&gt;&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;Oorspronkelijke waarde herstellen&lt;/td&gt;
 &lt;/tr&gt;
 &lt;/tbody&gt;
&lt;/table&gt;
&lt;h2 id="checklist"&gt;Checklist&lt;a class="anchor" href="#checklist"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Timing DChg ON/OFF&lt;/strong&gt; = &lt;code&gt;Enable&lt;/code&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;PDisChgMax&lt;/strong&gt; (Forced discharge power percentage) = &lt;code&gt;100%&lt;/code&gt;&lt;/li&gt;
&lt;/ul&gt;</description></item><item><title>Hinen</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/hinen/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/hinen/</guid><description>&lt;h1 id="hinen"&gt;Hinen&lt;a class="anchor" href="#hinen"&gt;#&lt;/a&gt;&lt;/h1&gt;
&lt;p&gt;Configuratie van de Hinen-omvormer met GbbOptimizer.&lt;/p&gt;
&lt;h2 id="mapping-van-gbboptimizer-modi-op-hinen-instellingen"&gt;Mapping van GbbOptimizer-modi op Hinen-instellingen&lt;a class="anchor" href="#mapping-van-gbboptimizer-modi-op-hinen-instellingen"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;p&gt;GbbOptimizer stuurt de Hinen-omvormer aan door de juiste &lt;strong&gt;Work Mode&lt;/strong&gt; en de laad-/ontlaadparameters in te stellen.&lt;/p&gt;
&lt;table&gt;
 &lt;thead&gt;
 &lt;tr&gt;
 &lt;th&gt;GbbOptimizer-bewerking&lt;/th&gt;
 &lt;th&gt;Work Mode&lt;/th&gt;
 &lt;th&gt;Charge/Discharge Enable&lt;/th&gt;
 &lt;th&gt;Start/End&lt;/th&gt;
 &lt;th&gt;SOC&lt;/th&gt;
 &lt;th&gt;Rate&lt;/th&gt;
 &lt;th&gt;AntiBackflow Enable&lt;/th&gt;
 &lt;th&gt;AntiBackflow Limit Rate&lt;/th&gt;
 &lt;/tr&gt;
 &lt;/thead&gt;
 &lt;tbody&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Normal&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Self-consumption&lt;/td&gt;
 &lt;td&gt;Nee&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;100%&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Charge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Time period control&lt;/td&gt;
 &lt;td&gt;Ja&lt;/td&gt;
 &lt;td&gt;Ja&lt;/td&gt;
 &lt;td&gt;Doel-SOC%&lt;/td&gt;
 &lt;td&gt;&lt;code&gt;ChargeLimit / (MaxInverterChargeDC of MaxBatteryChargeDC) * 100%&lt;/code&gt;&lt;/td&gt;
 &lt;td&gt;Nee&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Discharge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Time period control&lt;/td&gt;
 &lt;td&gt;Ja&lt;/td&gt;
 &lt;td&gt;Ja&lt;/td&gt;
 &lt;td&gt;Doel-SOC%&lt;/td&gt;
 &lt;td&gt;&lt;code&gt;DischargeLimit / (MaxInverterChargeDC of MaxBatteryChargeDC) * 100%&lt;/code&gt; (negatieve waarde)&lt;/td&gt;
 &lt;td&gt;Ja&lt;/td&gt;
 &lt;td&gt;Zelfde als Rate, maar &amp;gt; 0&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;DisableCharge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Time period control&lt;/td&gt;
 &lt;td&gt;Ja&lt;/td&gt;
 &lt;td&gt;Ja&lt;/td&gt;
 &lt;td&gt;Actuele SOC&lt;/td&gt;
 &lt;td&gt;1%&lt;/td&gt;
 &lt;td&gt;Nee&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="opmerkingen-over-de-discharge-bewerking"&gt;Opmerkingen over de Discharge-bewerking&lt;a class="anchor" href="#opmerkingen-over-de-discharge-bewerking"&gt;#&lt;/a&gt;&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;De waarde &lt;code&gt;DischargeLimit&lt;/code&gt; komt overeen met de parameter „Max &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/references/glossary/#gridsetpoint" class="glossary-term" title="Gewenste vermogensuitwisseling met het net in watt"&gt;GridSetpoint&lt;/a&gt; / Discharge (W)&amp;quot;&lt;/li&gt;
&lt;li&gt;Als de ontlading trager moet om het hele uur te beslaan, corrigeert het programma deze waarde automatisch&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;AntiBackflow&lt;/strong&gt; wordt ingeschakeld tijdens het ontladen om de export naar het net te beheersen&lt;/li&gt;
&lt;/ul&gt;</description></item><item><title>Sofar</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/sofar/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/installation/inverters/sofar/</guid><description>&lt;h1 id="sofar"&gt;Sofar&lt;a class="anchor" href="#sofar"&gt;#&lt;/a&gt;&lt;/h1&gt;
&lt;p&gt;Configuratie van de Sofar-omvormer met GbbOptimizer. De Sofar-omvormer wordt aangestuurd in &lt;strong&gt;Passive Mode&lt;/strong&gt;.&lt;/p&gt;
&lt;h2 id="mapping-van-gbboptimizer-modi-op-sofar-instellingen-passive-mode"&gt;Mapping van GbbOptimizer-modi op Sofar-instellingen (Passive Mode)&lt;a class="anchor" href="#mapping-van-gbboptimizer-modi-op-sofar-instellingen-passive-mode"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;p&gt;Het programma stelt &lt;code&gt;StorageMode = 3&lt;/code&gt; (Passive Mode) in en (bij ondersteuning van 5 parameters) &lt;code&gt;ManagementMode = 1&lt;/code&gt; (Manual).&lt;/p&gt;
&lt;table&gt;
 &lt;thead&gt;
 &lt;tr&gt;
 &lt;th&gt;Bewerking&lt;/th&gt;
 &lt;th&gt;Gdes (Grid setpoint)&lt;/th&gt;
 &lt;th&gt;Blo (battery high)&lt;/th&gt;
 &lt;th&gt;Bup (battery low)&lt;/th&gt;
 &lt;th&gt;Gdzup (grid high)&lt;/th&gt;
 &lt;th&gt;Gdzlo (grid low)&lt;/th&gt;
 &lt;/tr&gt;
 &lt;/thead&gt;
 &lt;tbody&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Normal&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Standaard-&lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/nl/references/glossary/#gridsetpoint" class="glossary-term" title="Gewenste vermogensuitwisseling met het net in watt"&gt;GridSetpoint&lt;/a&gt; (uit het menu Discharge)&lt;/td&gt;
 &lt;td&gt;ChargeLimit of MaxBatteryChargePower of MaxInverterChargePower&lt;/td&gt;
 &lt;td&gt;-(DischargeLimit of MaxBatteryDischargePower of MaxInverterDischargeLimit)&lt;/td&gt;
 &lt;td&gt;MaxBuyPower of MaxInverterChargePower&lt;/td&gt;
 &lt;td&gt;-(MaxSellPower of MaxInverterDischargePower)&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Charge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;= Gdzup&lt;/td&gt;
 &lt;td&gt;ChargeLimit (gecorrigeerd om TargetSOC in een heel uur te bereiken)&lt;/td&gt;
 &lt;td&gt;0&lt;/td&gt;
 &lt;td&gt;InputLimit of MaxBuyPower of MaxInverterChargePower&lt;/td&gt;
 &lt;td&gt;0&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Discharge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;= Gdzlo&lt;/td&gt;
 &lt;td&gt;= Bup&lt;/td&gt;
 &lt;td&gt;-(DischargeLimit, gecorrigeerd om TargetSOC in een heel uur te bereiken)&lt;/td&gt;
 &lt;td&gt;0&lt;/td&gt;
 &lt;td&gt;-(MaxSellPower of MaxInverterDischargePower)&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;DisableCharge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;0&lt;/td&gt;
 &lt;td&gt;0&lt;/td&gt;
 &lt;td&gt;0&lt;/td&gt;
 &lt;td&gt;MaxBuyPower of MaxInverterChargePower&lt;/td&gt;
 &lt;td&gt;-(MaxSellPower of MaxInverterDischargePower)&lt;/td&gt;
 &lt;/tr&gt;
 &lt;/tbody&gt;
&lt;/table&gt;
&lt;blockquote class='book-hint note'&gt;
&lt;p&gt;Als de optie „SofarSolar: Support for 5 parameters (not 3) in PassiveMode&amp;quot; niet is aangevinkt, worden de parameters &lt;strong&gt;Gdzup&lt;/strong&gt; en &lt;strong&gt;Gdzlo&lt;/strong&gt; niet gewijzigd (omdat ze niet beschikbaar zijn in de 3-parameter-modus).&lt;/p&gt;</description></item></channel></rss>