Mode Mapping — Sofar#
How GbbOptimizer modes translate to Sofar inverter settings in Passive Mode.
Passive Mode#
| Operation | Gdes (Grid setpoint) | Blo (Battery high) | Bup (Battery low) | Gdzup (Grid high) | Gdzlo (Grid low) |
|---|---|---|---|---|---|
| Normal | Default GridSetpoint (Discharge menu) | ChargeLimit or MaxBatteryChargePower or MaxInverterChargePower | -(DischargeLimit or MaxBatteryDischargePower or MaxInverterDischargeLimit) | MaxBuyPower or MaxInverterChargePower | -(MaxSellPower or MaxInverterDischargePower) |
| Charge | = Gdzup | ChargeLimit or MaxBatteryChargePower or MaxInverterChargePower (adjusted to reach target SOC in the full hour) | 0 | InputLimit or MaxBuyPower or MaxInverterChargePower | 0 |
| Discharge | = Gdzlo | = Bup | -(DischargeLimit or MaxBatteryDischargePower or MaxInverterDischargeLimit) (adjusted to reach target SOC in the full hour) | 0 | -(MaxSellPower or MaxInverterDischargePower) |
| DisableCharge | 0 | 0 | 0 | MaxBuyPower or MaxInverterChargePower | -(MaxSellPower or MaxInverterDischargePower) |
Parameters#
- Gdes — Grid setpoint: target grid energy exchange value
- Blo — Battery high: maximum battery charging power
- Bup — Battery low: maximum battery discharge power (negative value)
- Gdzup — Grid high: maximum grid import power
- Gdzlo — Grid low: maximum grid export power (negative value)
Notes#
If the option “SofarSolar: Support for 5 parameters (not 3) in PassiveMode” is unchecked, the Gdzup and Gdzlo parameters are not changed (because they are not available in 3-parameter mode).
The program sets:
StorageMode=3(PassiveMode)ManagementMode=1(Manual) — only when 5-parameter support is enabled