Sofar#
Configuring a Sofar inverter with GbbOptimizer. The Sofar inverter is controlled in Passive Mode.
GbbOptimizer mode mapping to Sofar settings (Passive Mode)#
The program sets StorageMode = 3 (Passive Mode) and (when supporting 5 parameters) ManagementMode = 1 (Manual).
| Operation | Gdes (Grid setpoint) | Blo (battery high) | Bup (battery low) | Gdzup (grid high) | Gdzlo (grid low) |
|---|---|---|---|---|---|
| Normal | Default GridSetpoint (from Discharge menu) | ChargeLimit or MaxBatteryChargePower or MaxInverterChargePower | -(DischargeLimit or MaxBatteryDischargePower or MaxInverterDischargeLimit) | MaxBuyPower or MaxInverterChargePower | -(MaxSellPower or MaxInverterDischargePower) |
| Charge | = Gdzup | ChargeLimit (adjusted to reach TargetSOC in the full hour) | 0 | InputLimit or MaxBuyPower or MaxInverterChargePower | 0 |
| Discharge | = Gdzlo | = Bup | -(DischargeLimit, adjusted to reach TargetSOC in the full hour) | 0 | -(MaxSellPower or MaxInverterDischargePower) |
| DisableCharge | 0 | 0 | 0 | MaxBuyPower or MaxInverterChargePower | -(MaxSellPower or MaxInverterDischargePower) |
If the option “SofarSolar: Support for 5 parameters (not 3) in PassiveMode” is unchecked, the Gdzup and Gdzlo parameters are not changed (because they are not available in 3-parameter mode).