<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Inverters on GbbOptimizer — Manual</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/</link><description>Recent content in Inverters on GbbOptimizer — Manual</description><generator>Hugo</generator><language>en</language><atom:link href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/index.xml" rel="self" type="application/rss+xml"/><item><title>Victron</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/victron/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/victron/</guid><description>&lt;h1 id="victron"&gt;Victron&lt;a class="anchor" href="#victron"&gt;#&lt;/a&gt;&lt;/h1&gt;
&lt;span class="badge" style="background-color: #3498db; color: white; padding: 2px 8px; border-radius: 4px; font-size: 0.75em; font-weight: 600; text-transform: uppercase; vertical-align: middle;"&gt;victron-only&lt;/span&gt;

&lt;p&gt;Configuring a Victron inverter with GbbOptimizer requires correct setup of the &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/references/glossary/#ess" class="glossary-term" title="Energy Storage System"&gt;ESS&lt;/a&gt; system and the &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/references/glossary/#vrm" class="glossary-term" title="Victron Remote Management portal"&gt;VRM&lt;/a&gt; portal.&lt;/p&gt;
&lt;h2 id="checklist"&gt;Checklist&lt;a class="anchor" href="#checklist"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;p&gt;Before starting GbbOptimizer, verify the following settings:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;&lt;strong&gt;Do not install Beta&lt;/strong&gt; firmware&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;DESS must be disabled&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Schedules&lt;/strong&gt; — the &amp;ldquo;Self-consumption above limit&amp;rdquo; option should be set to &lt;strong&gt;PV&lt;/strong&gt; (not &amp;ldquo;PV &amp;amp; Battery&amp;rdquo;). This ensures schedules do not cause battery discharge at night&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Battery Life&lt;/strong&gt; in &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/references/glossary/#ess" class="glossary-term" title="Energy Storage System"&gt;ESS&lt;/a&gt; must be &lt;strong&gt;disabled&lt;/strong&gt; — select mode: &lt;code&gt;Optimized (without BatteryLife)&lt;/code&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Log interval&lt;/strong&gt; (in VRM Online Portal) set to &lt;strong&gt;1 min&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;VRM permissions&lt;/strong&gt; — the user must have &lt;strong&gt;Full Control&lt;/strong&gt; enabled&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;Restart Cerbo&lt;/strong&gt; after making changes&lt;/li&gt;
&lt;/ol&gt;
&lt;blockquote class='book-hint warning'&gt;
&lt;p&gt;Incorrect Battery Life or Schedules settings can cause unexpected battery discharge at night.&lt;/p&gt;</description></item><item><title>Deye</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/deye/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/deye/</guid><description>&lt;h1 id="deye"&gt;Deye&lt;a class="anchor" href="#deye"&gt;#&lt;/a&gt;&lt;/h1&gt;
&lt;span class="badge" style="background-color: #9b59b6; color: white; padding: 2px 8px; border-radius: 4px; font-size: 0.75em; font-weight: 600; text-transform: uppercase; vertical-align: middle;"&gt;deye-only&lt;/span&gt;

&lt;p&gt;Deye hybrid inverters can be connected to GbbOptimizer in several ways. On this page you will find a checklist of inverter settings and a comparison of connection methods.&lt;/p&gt;
&lt;h2 id="checklist"&gt;Checklist&lt;a class="anchor" href="#checklist"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;p&gt;Before starting GbbOptimizer, verify the following on the Deye inverter:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;
&lt;p&gt;&lt;strong&gt;Operating mode&lt;/strong&gt; — &lt;code&gt;Zero export to CT&lt;/code&gt; or &lt;code&gt;Zero export to Loads&lt;/code&gt; (not &amp;ldquo;Selling First&amp;rdquo;!)&lt;/p&gt;</description></item><item><title>GoodWe</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/goodwe/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/goodwe/</guid><description>&lt;h1 id="goodwe"&gt;GoodWe&lt;a class="anchor" href="#goodwe"&gt;#&lt;/a&gt;&lt;/h1&gt;
&lt;p&gt;Configuring a GoodWe inverter with GbbOptimizer requires granting access through the SEMS portal and configuring on the GbbOptimizer side.&lt;/p&gt;
&lt;h2 id="step-by-step-configuration"&gt;Step-by-step configuration&lt;a class="anchor" href="#step-by-step-configuration"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;ol&gt;
&lt;li&gt;Log in to the &lt;strong&gt;SEMS&lt;/strong&gt; portal (GoodWe)&lt;/li&gt;
&lt;li&gt;In the &lt;strong&gt;Management&lt;/strong&gt; menu, in your plant data, add the email &lt;code&gt;gbbsoft@gbbsoft.pl&lt;/code&gt; as a &lt;strong&gt;Guest&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;In GbbOptimizer, add an installation with GoodWe, but &lt;strong&gt;do not select a SerialNo&lt;/strong&gt; — the list should be empty (except for the &amp;ldquo;Select SerialNo&amp;rdquo; label)&lt;/li&gt;
&lt;li&gt;At the bottom of the page, check &lt;strong&gt;Share installation with technical support&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;Contact technical support (e.g. via Discord: &lt;code&gt;gbbsoft&lt;/code&gt;) and provide your inverter&amp;rsquo;s &lt;strong&gt;SerialNo&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;Technical support will select your SerialNo&lt;/li&gt;
&lt;/ol&gt;
&lt;blockquote class='book-hint note'&gt;
&lt;p&gt;GoodWe configuration requires a one-time technical support intervention to link the inverter serial number to your installation.&lt;/p&gt;</description></item><item><title>Afore</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/afore/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/afore/</guid><description>&lt;h1 id="afore"&gt;Afore&lt;a class="anchor" href="#afore"&gt;#&lt;/a&gt;&lt;/h1&gt;
&lt;p&gt;Configuring an Afore inverter with GbbOptimizer. GbbOptimizer controls the Afore inverter via the &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/references/glossary/#modbus" class="glossary-term" title="Serial communication protocol for industrial devices"&gt;Modbus&lt;/a&gt; protocol.&lt;/p&gt;
&lt;h2 id="gbboptimizer-mode-mapping-to-afore-settings"&gt;GbbOptimizer mode mapping to Afore settings&lt;a class="anchor" href="#gbboptimizer-mode-mapping-to-afore-settings"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;table&gt;
 &lt;thead&gt;
 &lt;tr&gt;
 &lt;th&gt;Operation&lt;/th&gt;
 &lt;th&gt;Register&lt;/th&gt;
 &lt;th&gt;Value&lt;/th&gt;
 &lt;th&gt;After completion&lt;/th&gt;
 &lt;/tr&gt;
 &lt;/thead&gt;
 &lt;tbody&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;AC charging maximum SOC&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Charging: target &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/references/glossary/#maxsoc" class="glossary-term" title="Maximum target state of charge"&gt;MaxSOC&lt;/a&gt;&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;ACCharging start/end time (1-4)&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Charging: array of next 4 periods&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Forced charging start/end time (1-4)&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Charging: array of next 4 periods&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;ACCharging power percentage&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Charging: Input Limit&lt;/td&gt;
 &lt;td&gt;% of MaxBuyPower or MaxBatteryChargeDC&lt;/td&gt;
 &lt;td&gt;Restore original value&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Forced charging power percentage&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Charging: Charge Limit&lt;/td&gt;
 &lt;td&gt;% of MaxBatteryChargeDC&lt;/td&gt;
 &lt;td&gt;Restore original value&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Minimum SOC for forced discharge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Discharge: target &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/references/glossary/#minsoc" class="glossary-term" title="Minimum state of charge threshold"&gt;MinSOC&lt;/a&gt;&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Forced discharge start time (1-4)&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Discharge: array of next 4 periods&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Power grid power limit percentage&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Discharge: &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/references/glossary/#gridsetpoint" class="glossary-term" title="Target grid power exchange value in watts"&gt;GridSetpoint&lt;/a&gt;&lt;/td&gt;
 &lt;td&gt;% of MaxSellPower or MaxBatteryDischargeDC&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Maximum charging current&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Charge block: sets &lt;code&gt;0&lt;/code&gt;&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;Restore original value&lt;/td&gt;
 &lt;/tr&gt;
 &lt;/tbody&gt;
&lt;/table&gt;
&lt;h2 id="checklist"&gt;Checklist&lt;a class="anchor" href="#checklist"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;&lt;strong&gt;Timing DChg ON/OFF&lt;/strong&gt; = &lt;code&gt;Enable&lt;/code&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;PDisChgMax&lt;/strong&gt; (Forced discharge power percentage) = &lt;code&gt;100%&lt;/code&gt;&lt;/li&gt;
&lt;/ul&gt;</description></item><item><title>Hinen</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/hinen/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/hinen/</guid><description>&lt;h1 id="hinen"&gt;Hinen&lt;a class="anchor" href="#hinen"&gt;#&lt;/a&gt;&lt;/h1&gt;
&lt;p&gt;Configuring a Hinen inverter with GbbOptimizer.&lt;/p&gt;
&lt;h2 id="gbboptimizer-mode-mapping-to-hinen-settings"&gt;GbbOptimizer mode mapping to Hinen settings&lt;a class="anchor" href="#gbboptimizer-mode-mapping-to-hinen-settings"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;p&gt;GbbOptimizer controls the Hinen inverter by setting the appropriate &lt;strong&gt;Work Mode&lt;/strong&gt; and charge/discharge parameters.&lt;/p&gt;
&lt;table&gt;
 &lt;thead&gt;
 &lt;tr&gt;
 &lt;th&gt;GbbOptimizer operation&lt;/th&gt;
 &lt;th&gt;Work Mode&lt;/th&gt;
 &lt;th&gt;Charge/Discharge Enable&lt;/th&gt;
 &lt;th&gt;Start/End&lt;/th&gt;
 &lt;th&gt;SOC&lt;/th&gt;
 &lt;th&gt;Rate&lt;/th&gt;
 &lt;th&gt;AntiBackflow Enable&lt;/th&gt;
 &lt;th&gt;AntiBackflow Limit Rate&lt;/th&gt;
 &lt;/tr&gt;
 &lt;/thead&gt;
 &lt;tbody&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Normal&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Self-consumption&lt;/td&gt;
 &lt;td&gt;No&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;100%&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Charge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Time period control&lt;/td&gt;
 &lt;td&gt;Yes&lt;/td&gt;
 &lt;td&gt;Yes&lt;/td&gt;
 &lt;td&gt;Target SOC%&lt;/td&gt;
 &lt;td&gt;&lt;code&gt;ChargeLimit / (MaxInverterChargeDC or MaxBatteryChargeDC) * 100%&lt;/code&gt;&lt;/td&gt;
 &lt;td&gt;No&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Discharge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Time period control&lt;/td&gt;
 &lt;td&gt;Yes&lt;/td&gt;
 &lt;td&gt;Yes&lt;/td&gt;
 &lt;td&gt;Target SOC%&lt;/td&gt;
 &lt;td&gt;&lt;code&gt;DischargeLimit / (MaxInverterChargeDC or MaxBatteryChargeDC) * 100%&lt;/code&gt; (negative value)&lt;/td&gt;
 &lt;td&gt;Yes&lt;/td&gt;
 &lt;td&gt;Same as Rate, but &amp;gt; 0&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;DisableCharge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Time period control&lt;/td&gt;
 &lt;td&gt;Yes&lt;/td&gt;
 &lt;td&gt;Yes&lt;/td&gt;
 &lt;td&gt;Current SOC&lt;/td&gt;
 &lt;td&gt;1%&lt;/td&gt;
 &lt;td&gt;No&lt;/td&gt;
 &lt;td&gt;—&lt;/td&gt;
 &lt;/tr&gt;
 &lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="notes-on-the-discharge-operation"&gt;Notes on the Discharge operation&lt;a class="anchor" href="#notes-on-the-discharge-operation"&gt;#&lt;/a&gt;&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;The &lt;code&gt;DischargeLimit&lt;/code&gt; value corresponds to the &amp;ldquo;Max &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/references/glossary/#gridsetpoint" class="glossary-term" title="Target grid power exchange value in watts"&gt;GridSetpoint&lt;/a&gt; / Discharge (W)&amp;rdquo; parameter&lt;/li&gt;
&lt;li&gt;If the discharge must be slower to last the full hour, the program automatically corrects this value&lt;/li&gt;
&lt;li&gt;&lt;strong&gt;AntiBackflow&lt;/strong&gt; is enabled during discharge to control grid export&lt;/li&gt;
&lt;/ul&gt;</description></item><item><title>Sofar</title><link>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/sofar/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/installation/inverters/sofar/</guid><description>&lt;h1 id="sofar"&gt;Sofar&lt;a class="anchor" href="#sofar"&gt;#&lt;/a&gt;&lt;/h1&gt;
&lt;p&gt;Configuring a Sofar inverter with GbbOptimizer. The Sofar inverter is controlled in &lt;strong&gt;Passive Mode&lt;/strong&gt;.&lt;/p&gt;
&lt;h2 id="gbboptimizer-mode-mapping-to-sofar-settings-passive-mode"&gt;GbbOptimizer mode mapping to Sofar settings (Passive Mode)&lt;a class="anchor" href="#gbboptimizer-mode-mapping-to-sofar-settings-passive-mode"&gt;#&lt;/a&gt;&lt;/h2&gt;
&lt;p&gt;The program sets &lt;code&gt;StorageMode = 3&lt;/code&gt; (Passive Mode) and (when supporting 5 parameters) &lt;code&gt;ManagementMode = 1&lt;/code&gt; (Manual).&lt;/p&gt;
&lt;table&gt;
 &lt;thead&gt;
 &lt;tr&gt;
 &lt;th&gt;Operation&lt;/th&gt;
 &lt;th&gt;Gdes (Grid setpoint)&lt;/th&gt;
 &lt;th&gt;Blo (battery high)&lt;/th&gt;
 &lt;th&gt;Bup (battery low)&lt;/th&gt;
 &lt;th&gt;Gdzup (grid high)&lt;/th&gt;
 &lt;th&gt;Gdzlo (grid low)&lt;/th&gt;
 &lt;/tr&gt;
 &lt;/thead&gt;
 &lt;tbody&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Normal&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;Default &lt;a href="https://krzysztofhajdamowicz.github.io/rewrite-GbbOptimizer-manual/en/references/glossary/#gridsetpoint" class="glossary-term" title="Target grid power exchange value in watts"&gt;GridSetpoint&lt;/a&gt; (from Discharge menu)&lt;/td&gt;
 &lt;td&gt;ChargeLimit or MaxBatteryChargePower or MaxInverterChargePower&lt;/td&gt;
 &lt;td&gt;-(DischargeLimit or MaxBatteryDischargePower or MaxInverterDischargeLimit)&lt;/td&gt;
 &lt;td&gt;MaxBuyPower or MaxInverterChargePower&lt;/td&gt;
 &lt;td&gt;-(MaxSellPower or MaxInverterDischargePower)&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Charge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;= Gdzup&lt;/td&gt;
 &lt;td&gt;ChargeLimit (adjusted to reach TargetSOC in the full hour)&lt;/td&gt;
 &lt;td&gt;0&lt;/td&gt;
 &lt;td&gt;InputLimit or MaxBuyPower or MaxInverterChargePower&lt;/td&gt;
 &lt;td&gt;0&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;Discharge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;= Gdzlo&lt;/td&gt;
 &lt;td&gt;= Bup&lt;/td&gt;
 &lt;td&gt;-(DischargeLimit, adjusted to reach TargetSOC in the full hour)&lt;/td&gt;
 &lt;td&gt;0&lt;/td&gt;
 &lt;td&gt;-(MaxSellPower or MaxInverterDischargePower)&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 &lt;td&gt;&lt;strong&gt;DisableCharge&lt;/strong&gt;&lt;/td&gt;
 &lt;td&gt;0&lt;/td&gt;
 &lt;td&gt;0&lt;/td&gt;
 &lt;td&gt;0&lt;/td&gt;
 &lt;td&gt;MaxBuyPower or MaxInverterChargePower&lt;/td&gt;
 &lt;td&gt;-(MaxSellPower or MaxInverterDischargePower)&lt;/td&gt;
 &lt;/tr&gt;
 &lt;/tbody&gt;
&lt;/table&gt;
&lt;blockquote class='book-hint note'&gt;
&lt;p&gt;If the option &amp;ldquo;SofarSolar: Support for 5 parameters (not 3) in PassiveMode&amp;rdquo; is unchecked, the &lt;strong&gt;Gdzup&lt;/strong&gt; and &lt;strong&gt;Gdzlo&lt;/strong&gt; parameters are not changed (because they are not available in 3-parameter mode).&lt;/p&gt;</description></item></channel></rss>