Hinen#

Configuring a Hinen inverter with GbbOptimizer.

GbbOptimizer mode mapping to Hinen settings#

GbbOptimizer controls the Hinen inverter by setting the appropriate Work Mode and charge/discharge parameters.

GbbOptimizer operationWork ModeCharge/Discharge EnableStart/EndSOCRateAntiBackflow EnableAntiBackflow Limit Rate
NormalSelf-consumptionNo100%
ChargeTime period controlYesYesTarget SOC%ChargeLimit / (MaxInverterChargeDC or MaxBatteryChargeDC) * 100%No
DischargeTime period controlYesYesTarget SOC%DischargeLimit / (MaxInverterChargeDC or MaxBatteryChargeDC) * 100% (negative value)YesSame as Rate, but > 0
DisableChargeTime period controlYesYesCurrent SOC1%No

Notes on the Discharge operation#

  • The DischargeLimit value corresponds to the “Max GridSetpoint / Discharge (W)” parameter
  • If the discharge must be slower to last the full hour, the program automatically corrects this value
  • AntiBackflow is enabled during discharge to control grid export