Afore#
Configuring an Afore inverter with GbbOptimizer. GbbOptimizer controls the Afore inverter via the Modbus protocol.
GbbOptimizer mode mapping to Afore settings#
| Operation | Register | Value | After completion |
|---|---|---|---|
| AC charging maximum SOC | Charging: target MaxSOC | — | — |
| ACCharging start/end time (1-4) | Charging: array of next 4 periods | — | — |
| Forced charging start/end time (1-4) | Charging: array of next 4 periods | — | — |
| ACCharging power percentage | Charging: Input Limit | % of MaxBuyPower or MaxBatteryChargeDC | Restore original value |
| Forced charging power percentage | Charging: Charge Limit | % of MaxBatteryChargeDC | Restore original value |
| Minimum SOC for forced discharge | Discharge: target MinSOC | — | — |
| Forced discharge start time (1-4) | Discharge: array of next 4 periods | — | — |
| Power grid power limit percentage | Discharge: GridSetpoint | % of MaxSellPower or MaxBatteryDischargeDC | — |
| Maximum charging current | Charge block: sets 0 | — | Restore original value |
Checklist#
- Timing DChg ON/OFF =
Enable - PDisChgMax (Forced discharge power percentage) =
100%